G-Etronax EP 11 - Sheets
|
|
 |
 |
 |
 |
 |
 |
 |
| Components: |
Glass fabric - Epoxy |
Back |
| Colour: |
Green |
|
| Serial No: |
360 |
|
| IEC 60893: |
EP GC 308 |
Print version |
| DIN 7735: |
Hgw 2372.4 |
|
| NEMA LI 1: |
G-11 |
|
|
Previous
| Next
|
| |
 |
 |
|
|
|
Testmethod |
Thickness |
Value |
Unit |
|
| Flexural strength at RT |
 |
ISO 178 |
≥1,6 mm |
450 |
MPa |
* 1 |
| Flexural strength at elevated temp. |
 |
ISO 178 |
≥1,6 mm |
300 D) |
MPa |
- |
| Modulus of elasticity |
 |
ISO 178 |
≥1,6 mm |
20.000 |
MPa |
* 1 |
| Compressive strength |
 |
ISO 604 |
≥5,0 mm |
550 |
MPa |
* 1 |
| Izod impact strength, parallel |
 |
ISO 180/2A |
≥5,0 mm |
65 |
KJ/m2 |
* 1 |
| Shearing strength, parallel |
 |
IEC 60893-2 |
≥5,0 mm |
55 |
MPa |
* 1 |
| Tensile strength |
|
ISO 527 |
≥1,6 mm |
320 |
MPa |
* 1 |
 |
| Electrical properties |
|
Testmethod |
Thickness |
Value |
Unit |
|
| Electric strength in oil at 90°C |
 |
IEC 243-1 |
3,0 mm |
18 |
kV/mm |
* 2 |
| Electric strength in oil at 90°C |
 |
IEC 243-1 |
≥3,0 mm |
60 |
kV/25mm |
* 2 |
| Permittivity 50 Hz |
|
IEC 250 |
≤3,0 mm |
5,0 |
|
* 3 |
| Permittivity 1 MHz |
|
IEC 250 |
≤3,0 mm |
5,0 |
|
* 3 |
| Dissipation factor 50 Hz |
|
IEC 250 |
≤3,0 mm |
0,008 |
|
* 3 |
| Dissipation factor 1 MHz |
|
IEC 250 |
≤3,0 mm |
0,01 |
|
* 3 |
| Insulation resistance after immersion in water |
|
IEC 167 |
All |
500.000 |
MΩ |
* 4 |
| Comparative tracking index |
|
IEC 112 |
≥3,0 mm |
200 |
CTI |
* 1 |
 |
| Physical and thermal properties |
|
|
Testmethod |
Thickness |
Value |
Unit |
|
| Thermal endurance index 20.000 h |
|
IEC 216 |
≥3,0 mm |
180 |
T.I. |
- |
| Flammability |
|
IEC 707 |
3,0 mm |
- |
|
- |
| Density |
|
IEC 1183-A |
All |
1,85 |
g/cm3 |
* 1 |
| Water absorption |
|
IEC 62-1 |
50x50x3 mm |
15 |
mg |
* 4 |
 |
| Characteristics and applications |
 |
| High resistance to chemicals. Particularly good, lasting strength properties and insulation values even at high application temperatures. Radiation-resistant. Can be used at cryogenic temperatures. Insulation and construction material in electrical machinery, tranformers and chemical plants. |
|
 |
 |
Notes: A) Thickness > 8mm. B) Thickness ≥ 4,0mm C) 1 h/130°C / measured at 130°C D) 1 h/150°C / measured at 150°C E) 1 h/180°C / measured at 180°C F) 1 h/200°C / measured at 200°C
|
* Conditioning: 1: 24h/23°C/50%RH 2: 24h/23°C/50%RH + 1h/Oil 90°C 3: 96h/105°C + 1h/23°C/20%RH 4: 24h/50°C + 24h/water 23°C 5: 96h/105°C + 1h/Oil 90° |
 |
 |
 |
| The above values are average values based on the results of extensive testing in our laboratories. ELEKTRO-ISOLA A/S cannot accept responsibility for the performance of our products in applications over which we have no control. |
|
|