Thermal class H insulation material. Stable material with a long service life under the most demanding conditions. High chemical resistance, even at high temperatures.
Closest relevant standards
IEC 60893:EP GC 308
NEMA LI 1:G-11
DIN 7735:Hgw 2372.4
A thermal class H insulation material used for rotary pump vains and laminations. It also retains high chemical resistance even at elevated temperatures.
Only available as sheet.
EP 11 and EP 215 S share the same glass-fabric reinforcement and underlying standard (EP GC 308), and the two are built to comparable mechanical and electrical figures on paper. EP 215 S uses a different resin/additive combination in the epoxy, which is what makes it far better suited to rotary vains than EP 11.
Suitable for electrical insulation and other electrical applications.
Suitable for applications where the materials are exposed to mechanical impact.
The material remains functional and retains its properties even at high temperatures.
Resistant material with long service life.
| Mechanical properties | Test method | Thickness | Value | Unit | Note |
|---|---|---|---|---|---|
| Bending strength at RT | ISO 178 | ≥ 1,5 mm | 430 | MPa | *1 |
| Bending strength at a high temperature | ISO 178 | ≥ 1,5 mm | 300 | MPa | *B |
| Modulus of elasticity | ISO 178 | ≥ 1,5 mm | 22000 | MPa | *1 |
| Compressive strength | ISO 604 | ≥ 5 mm | 550 | MPa | *1 |
| Izod impact strength, parallel with layers | ISO 180/2A | ≥ 5 mm | 60 | Kj/m2 | *1 |
| Shearing strength, parallel | IEC 60893-2 | ≥ 5 mm | 55 | MPa | *1 |
| Tensile strength | ISO 527 | ≥ 1,6 mm | 320 | MPa | *1 |
| Electrical properties | Test method | Thickness | Value | Unit | Note |
|---|---|---|---|---|---|
| Electrical strength in oil at 90°C, perpendicular | IEC 60243-1 | 3 mm | 18 | kV/mm | *2 |
| Electrical strength in oil at 90°C, parallel | IEC 60243-1 | ≥ 3 mm | 70 | kV/25mm | *2 |
| Permitivity 50Â MHz | IEC 62631-2-1 | ≤ 3 mm | 5 | *3 | |
| Permitivity 1Â MHz | IEC 62631-2-1 | ≤ 3 mm | 5 | *3 | |
| Dissipation factor 50Â MHz | IEC 62631-2-1 | ≤ 3 mm | 0.008 | *3 | |
| Dissipation factor 1Â MHz | IEC 62631-2-1 | ≤ 3 mm | 0.01 | *3 | |
| Insulation resistance after submersion in water | IEC 62631-3-3 | All | 500000 | MΩ | *4 |
| Comparative tracking index | IEC 60112 | ≥ 3 mm | 200 | CTI | *1 |
| Physical and thermal properties | Test method | Thickness | Value | Unit | Note |
|---|---|---|---|---|---|
| Temperature index 20,000 h (T.I.) | IEC 60216 | ≥ 3 mm | 180 | °C | * |
| Fire class | IEC 60695-11-10 | * | |||
| Density | ISO 1183-A | All | 1.85 | g/cm³ | * |
| Water absorption | ISO 62-1 | 50x50x3 mm | 15 | mg | * |
| Smoke emission & toxicity | EN 45545-2; R22, R23 & R24 | * | |||
| Oxygen Index (OI) | EN ISO 4589-2 | % | |||
| Smoke density (Ds max.) | EN ISO 5659-2 | * | |||
| Smoke density (Ds max.) | EN ISO 5659-2 | * | |||
| Toxicity (CITNLP) | NF X 70-100-1/-2 | * | |||
| Toxicity (CITG, 8 min) | EN 17084 | * |
The above values are average values resulting from extensive tests in our laboratories. ELEKTRO-ISOLA A/S disclaims any and all liability for the performance of our materials in applications outside our control. Elektro-Isola A/S reserves the right to modify the above data without notice or further information. Furthermore, we refer to our general disclaimer.
* Note that color and surface are indicative. As this is a technical product, colour and expression may vary according to dimensions, batches and machining. If you want further information or have special decorative needs, please feel free to contact us.